15 results.
-
Guide · Electrical engineering
How a fire alarm system works
A building fire alarm system watches for signs of fire, decides what each signal means, warns the people inside and, if it is monitored, calls for help. It also watches itself, so a cut wire or a dead battery shows up as a trouble signal instead of a silent …
-
Guide · Electrical engineering
Fire alarm interfaces with HVAC, doors and elevators
When a fire alarm system goes into alarm, it does more than sound signals. It shuts down or switches fans, releases fire doors, unlocks doors on exit routes and sends elevators to a safe floor. These interfaces are where the fire alarm meets other trades, and …
-
Service · Electrical engineering
Fire alarm system design
A fire alarm system has one job: detect a fire early, warn everyone in the building and call for help, every time. We design fire alarm systems for new buildings, renovations, tenant fit-outs and replacements of ageing panels, working from the codes and …
-
Guide · Electrical engineering
Addressable vs conventional fire alarm systems
A conventional fire alarm system tells you which zone an alarm came from. An addressable system tells you which device, by name and location. That difference changes how the system is wired, how quickly staff and firefighters find a fire, how false alarms are …
-
Guide · Electrical engineering
Access control, door hardware and safe egress
… to make it hard to get into a building; it is not allowed to make it hard to get out. Building and fire codes limit how exit doors can be locked, require many electrified locks to release on fire alarm or power failure, and protect the function of fire doors. …
-
Guide · Electrical engineering
Fire alarm devices: detectors, pull stations and signals
Fire alarm devices fall into two groups: initiating devices that start an alarm, such as detectors, pull stations and sprinkler switches, and notification appliances that warn people, such as horns, speakers and strobes. Each type suits some spaces and not …
-
Guide · Electrical engineering
How access control works
… releases the lock for a few seconds. If no, it stays locked. Record. Every grant, refusal and door alarm is logged with the time, door and credential. It also watches the door itself. A switch in the frame tells the controller whether the door is open or …
-
Guide · Electrical engineering
Electrical permits and inspections
… that add or move wiring. Generators, transfer switches, solar PV, energy storage and EV chargers. Fire alarm, emergency lighting and other life safety electrical work. Electrical work for new mechanical equipment, such as heat pumps and rooftop units. Small …
-
Service · Electrical engineering
VESDA and OSID smoke detection
… detection and open-area imaging beam detection for those spaces, integrated with the building's fire alarm system and set up so the early warnings they give actually reach someone. VESDA and OSID are trademarks of their owners, Xtralis, now part of Honeywell. …
-
Guide · Electrical engineering
How aspirating smoke detection (VESDA) works
… produces a trouble signal. A filter removes dust and larger particles that would cause nuisance alarms and contaminate the chamber. The detection chamber shines a light source, commonly a laser, through the air sample. Smoke particles scatter the light, and a …
-
Guide · Electrical engineering
Where very early smoke detection makes sense
Very early smoke detection makes sense where a small fire would cause a large loss, such as data rooms, telecom rooms, archives and critical electrical rooms, and where ordinary detectors cannot do their job, such as high-airflow rooms and very tall spaces. …
-
Guide · Electrical engineering
Electrical design for tenant renovations
… service. Once capacity is confirmed, the design covers new power and lighting, changes to fire alarm and emergency lighting, the demolition of old wiring and the records that keep the building's drawings accurate for the next tenant. Tenant fit-outs are where …
-
Guide · Electrical engineering
Canadian Electrical Code basics for owners
… adopts it, usually with its own amendments, and it is enforced through electrical permits and inspections. For owners, the practical points are simple: new electrical work must meet the edition in force, it must use certified equipment, and it must be done by …
-
Guide · Electrical engineering
Emergency lighting design
… unit equipment, and generators supplying emergency loads are installed to CSA C282. The National Fire Code and provincial fire codes then set inspection and testing. Exact requirements depend on the edition adopted where you are, so confirm them for each …
-
Service · Electrical engineering
Electrical design for buildings
… with nameplate data if you have it. Any previous studies: arc flash, coordination, thermography or inspection reports. What you get A set of drawings and specifications that a licensed contractor can price and build from, sealed for permit where required. A …
Not finding it? Ask us or call 1-833-888-0091.