Fire protection systems in Canadian buildings must be installed, verified, monitored and inspected to specific standards, and much of that work has to be done by qualified fire protection technicians. We give owners an independent view of their fire protection systems and the paperwork behind them, and we coordinate the required verification, testing and monitoring so nothing falls through the cracks.

Fire protection is spread across many contractors and many standards: alarm systems, sprinklers, standpipes, extinguishers, emergency lighting, fire separations and the fire safety plan. Each has its own inspection schedule. Owners are responsible for all of it, and gaps are easy to miss until a fire inspector or an insurer asks for records.

How this fits with mandated work. The National Fire Code of Canada and provincial fire codes require fire alarm systems to be verified under CAN/ULC-S537 when installed or changed, and inspected and tested annually under CAN/ULC-S536. Sprinklers and other systems have their own required inspections. These are done by qualified technicians and reviewed by the local fire authority. We do not replace them. We review the condition of your systems independently, help you prepare, coordinate the qualified contractors and follow up until deficiencies are closed.

What we look at

  • Fire alarm systems: panel condition and trouble signals, devices, annunciators, and the most recent verification and annual inspection reports.
  • Monitoring: whether the system is connected to a monitoring station, what signals are sent and when the connection was last tested.
  • Sprinkler and standpipe systems: visible condition, valves and their supervision, signage, and inspection records.
  • Portable fire extinguishers: placement, access, tags and monthly checks.
  • Emergency lighting and exit signs: operation and test records.
  • Fire separations and doors: closers, latching, hold-open devices and penetrations through rated assemblies, where visible.
  • Fire safety plan and records: whether a plan exists, is current, and matches the building as it is used today.

How the pieces connect

A fire alarm system is easiest to understand as a chain of signals. Detectors, pull stations and sprinkler flow switches send alarm signals to the control panel; valve tamper switches send supervisory signals; faults in wiring or power show up as trouble signals. The panel sounds the building's notification appliances and, where the building is monitored, passes the signals to a monitoring station that calls the fire department. Verification under CAN/ULC-S537 proves the whole chain when it is installed or changed, and the annual inspection under CAN/ULC-S536 tests it again every year.

Smoke detectors alarm Pull stations alarm Flow switch alarm (sprinklers) Valve tamper supervisory Fire alarm panel control unit Notification bells, horns, strobes Monitoring station receives signals Fire department sound signals dispatch call alarm, supervisory and trouble signals
The signal chain. Initiating devices send alarm signals and valve tamper switches send supervisory signals to the panel; the panel sounds the building and, where monitored, passes alarm, supervisory and trouble signals to a monitoring station that calls the fire department. Verification proves the whole chain when it is installed or changed; the annual inspection tests it again.

How it works

  1. We start with why. A fire inspection order, a change of use, a renovation, a purchase or a new property manager each lead to a different scope.
  2. Record review. We gather verification reports, annual inspection reports, monitoring agreements and the fire safety plan.
  3. Site walkthrough. We inspect visible systems and conditions throughout the building and note discrepancies with the records.
  4. Coordination. Where verification, annual testing or monitoring changes are needed, we bring in qualified fire protection contractors and manage the schedule.
  5. Close-out. We track deficiencies through to correction and assemble the records in one place.

What to have ready

  • The most recent fire alarm verification report and annual inspection reports, with their deficiency lists.
  • Sprinkler, standpipe and fire pump inspection and test reports.
  • The monitoring agreement and the last test of the connection to the monitoring station.
  • Extinguisher service tags and emergency lighting test records.
  • The fire safety plan, and any fire inspection orders or insurer letters.
  • Drawings or details of any renovations since the last verification.

What you get

A written report on the state of your fire protection systems and records, a list of open deficiencies and who should correct them, and a schedule showing which inspections and tests are due and when. When we coordinate contractors, you also get the completed reports filed together, so you can answer a fire inspector's or insurer's request quickly.

For owners with more than one building, a consistent record set across the portfolio makes it much easier to see which sites are up to date and which need attention.

A typical case

A tenant renovates a floor of an office building, moving walls and adding a server room. The contractor relocates some smoke detectors and adds others, but nobody arranges for the fire alarm changes to be verified. A year later, the annual inspection technician notes devices that do not match the system drawings and a zone description at the annunciator that no longer makes sense.

Sorting this out involves several parties. The fire alarm contractor needs to verify the modified portion of the system and update the documentation. The annunciator zone descriptions and the monitoring station's records may need to be changed so that a signal from that floor sends responders to the right place. The fire safety plan may need updating if the layout or the exits changed. Coordination keeps those pieces in order and makes sure the final records agree with each other and with the building as it now stands.

The lesson for owners is that any change touching the fire alarm, sprinklers or fire separations should trigger a question: does this need verification, testing or a record update before the space is occupied?

Who it's for

  • Property and facility managers responsible for fire code compliance.
  • Owners who have received a fire inspection order or insurer request.
  • Tenants making changes to a space that affect the fire alarm or sprinklers.
  • Condominium boards and owners of multi-unit residential buildings.

Learn more in our guides to fire alarm system inspections, fire alarm verification, how fire alarm monitoring works and sprinkler system inspections.

Common questions

What is the difference between verification and an annual inspection?

Verification is a complete check of a new or modified fire alarm system to confirm it was installed and works as designed. The annual inspection is the recurring test of an existing system. Both are done by qualified technicians under their respective CAN/ULC standards.

Do you issue fire alarm verification certificates?

No. Verification is done by qualified fire alarm technicians and their companies. We coordinate that work and track the results for you.

Does every building need fire alarm monitoring?

Not every building is required to have it. Requirements depend on the building type, occupancy and the codes in force where it is located. Your local fire authority can confirm what applies.

What happens if the monitoring connection fails?

The panel should report a trouble condition and the monitoring station should notice the lost connection, depending on how the system communicates. Either way, an unmonitored building is a problem that should be fixed quickly and checked when the system is tested.