Guide · Building systems
Commissioning a new building
… many trades, each focused on their own scope. Mechanical, electrical, controls, plumbing and fire protection systems all have to work together, and the gaps between contracts are where problems hide. Typical results of skipping commissioning include equipment …
-
Guide · Wireless & communications
Coordinating low-voltage work in construction
… and voice WiFi and in-building cellular systems Security cameras, access control and intrusion alarms Audio-visual systems, paging and digital signage Building automation and metering networks Nurse call, intercom and other specialty systems Fire alarm is …
-
Guide · Inspections
The real cost of deferred maintenance
… that need system shutdowns Uninspected electrical connections Overheating, unplanned outages and fire risk Our guide to parking garage inspections covers one area where deferral is especially costly. The hidden costs The repair bill is only part of the cost. …
-
Guide · Inspections
Reserve fund studies and capital planning
… systems, domestic hot water and drainage. Electrical distribution, lighting and standby power. Fire alarm, sprinklers and other life safety systems. Elevators. Interior common areas and amenities. For each, the study estimates the cost to repair or replace it …
-
Guide · Wireless & communications
Data centre power and UPS
… common because they last longer, weigh less and take up less space, though they have their own fire safety and code requirements. Either way, batteries age, and heat shortens their life considerably. Battery rooms and cabinets need appropriate cooling, …
-
Guide · Building systems
Switchgear and panel maintenance
… keeps protective devices working as designed and finds problems before they become outages or fires. Why maintenance matters Distribution equipment has two jobs: carry current every day, and interrupt it safely when there is a fault. The first job can be …
-
Guide · Building systems
Building automation systems
… electrical systems: it starts and stops equipment, holds temperatures and pressures, and raises alarms. When it is set up and maintained well, it saves energy and keeps occupants comfortable. When it drifts, it can quietly waste a great deal of both. What a …
-
Guide · Building systems
Automatic transfer switches
… loads Larger buildings often have more than one ATS. Life safety loads such as emergency lighting, fire alarm and fire pumps may be on separate transfer switches from loads like elevators, heating or business equipment, and the electrical code requires …
-
Guide · Electrical engineering
Emergency lighting design
… unit equipment, and generators supplying emergency loads are installed to CSA C282. The National Fire Code and provincial fire codes then set inspection and testing. Exact requirements depend on the edition adopted where you are, so confirm them for each …
-
Guide · Building systems
Generator load bank testing
… specified load, and allows a load bank to be used where the building load is too low. The National Fire Code of Canada and provincial fire codes reference these requirements. Check the current edition and what your province and local fire authority require, …
-
Guide · Building systems
Diesel fuel quality and storage
… sediment Degradation products, rust or dirt Check filters, consider polishing and a tank inspection A sample jar is a screening check, not a lab result. Fuel that looks clean can still fail stability or microbial tests, so keep up the laboratory testing set …
-
Guide · Safety
Managing contractor safety
… tasks, including trade certifications and licences Insurance appropriate to the work Equipment inspection and maintenance practices Match the depth of checking to the risk. A contractor painting an office does not need the same scrutiny as one doing hot work …
-
Service · Electrical engineering
Electrical design for buildings
… with nameplate data if you have it. Any previous studies: arc flash, coordination, thermography or inspection reports. What you get A set of drawings and specifications that a licensed contractor can price and build from, sealed for permit where required. A …
-
Guide · Building systems
Rooftop unit maintenance
… A cracked or corroded heat exchanger can let combustion products into the supply air. Have gas-fired units inspected by a licensed gas technician before each heating season, and make sure the spaces they serve have working carbon monoxide detection where …
-
Guide · Building systems
Heat pumps in cold climates
… mornings and during defrost cycles. Whether ice builds up under or around the outdoor unit. Any alarms, lockouts or unusual noise. Electricity use compared with expectations, if you have interval metering. Small adjustments to switchover settings and defrost …
-
Guide · Building systems
Where to place an AED
… people pass and will remember seeing it Near other emergency equipment such as first aid kits, fire extinguishers or pull stations, where that makes sense Accessible whenever the space is occupied, not in a locked office or behind a reception desk that closes …